¡Seguimos de Cyberdays! Hasta 40% OFF + 3 cuotas sin interés con MP  Ver más

Enviar a
C.A.B.A., Ciudad Autónoma de Buenos Aires
0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional

Selecciona tu país

América

Europa

Resto del mundo

portada Simulation of the Dynamics of a Wind-Driven Fire in a Ranch-Style House - Texas (en Inglés)
Formato
Libro Físico
Autor
Editorial
Idioma
Inglés
N° páginas
90
Encuadernación
Tapa Blanda
Dimensiones
28.0 x 21.6 x 0.5 cm
Peso
0.23 kg.
ISBN13
9781496136602

Simulation of the Dynamics of a Wind-Driven Fire in a Ranch-Style House - Texas (en Inglés)

Nist (Autor) · Createspace · Tapa Blanda

Simulation of the Dynamics of a Wind-Driven Fire in a Ranch-Style House - Texas (en Inglés) - Nist

Libro Nuevo Importado
Envío: 17 a 23 días háb.
$ 108.937$ 65.362
-40%
Costos de importación incluídos en el precio ✅
Libro Nuevo

Quedan más de 100 unidades

$ 65.362
Llega entre el 04 Ago y el 12 Ago a C.A.B.A., Ciudad Autónoma de Buenos Aires. Seleccionar ubicación

Reseña del libro "Simulation of the Dynamics of a Wind-Driven Fire in a Ranch-Style House - Texas (en Inglés)"

This report describes the results of calculations using the NIST Fire Dynamics Simulator (FDS) performed to provide insight on the thermal conditions that may have occurred during a wind-driven fire in a one-story ranch house on April 12, 2009 in Houston, Texas. The FDS simulations represented the building geometry, material thermal properties, and fire behavior based on information gathered from multiple sources. The simulation results are provided in this report. The FDS simulation that best represents the witnessed fire conditions indicate that fire spread throughout the attic and first floor developed a wind-driven flow with temperatures in excess of 260 C (500 F) between the den and front door. The critical event in this fire was the creation of a wind-driven flow path between a large span of failed windows on the upwind side of the structure, and the open front door on the downwind side of the structure. Floor-to-ceiling temperatures rapidly increased in the flow path, in which members were performing interior operations. In a simulation without wind, the flow path was not created after the large span of windows failed, and the thermal environment surrounding the location of interior operations improved.

Opiniones del libro

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes