¡Todavía hay mucho por celebrar! Hasta 50% OFF + 3 cuotas sin interés  Ver más

Enviar a
C.A.B.A., Ciudad Autónoma de Buenos Aires
0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional

Selecciona tu país

América

Europa

Resto del mundo

portada Method Development and Validation for Voriconazole Estimation: Rp-Hplc and uv Spectrophotometric Methods in Bulk and Pharmaceutical Formulations (en Inglés)
Formato
Libro Físico
Idioma
Inglés
N° páginas
80
Encuadernación
Tapa Blanda
ISBN13
9783330051331

Method Development and Validation for Voriconazole Estimation: Rp-Hplc and uv Spectrophotometric Methods in Bulk and Pharmaceutical Formulations (en Inglés)

Yarguntla Srinivasa Rao; K. Vara Prasada Rao (Autor) · Lap Lambert Academic Publishing · Tapa Blanda

Method Development and Validation for Voriconazole Estimation: Rp-Hplc and uv Spectrophotometric Methods in Bulk and Pharmaceutical Formulations (en Inglés) - Yarguntla Srinivasa Rao; K. Vara Prasada Rao

Libro Nuevo Importado
Envío: 24 a 29 días háb.
$ 179.509$ 89.754
-50%
Costos de importación incluídos en el precio ✅
Libro Nuevo

Quedan 10 unidades

$ 89.754
Llega entre el 01 Oct y el 08 Oct a C.A.B.A., Ciudad Autónoma de Buenos Aires. Seleccionar ubicación

Reseña del libro "Method Development and Validation for Voriconazole Estimation: Rp-Hplc and uv Spectrophotometric Methods in Bulk and Pharmaceutical Formulations (en Inglés)"

A rapid, sensitive, and specific RP-HPLC method with UV detection was developed and validated for the determination of voriconazole. Chromatography was performed on an Enable C18 G column (250 × 4.6 mm) in isocratic mode, using a mobile phase of methanol and acetonitrile (60:40, v/v). The flow rate was set at 1 mL/min, and the effluent was monitored at 223 nm. Chromatographic analysis revealed a main peak for voriconazole at a retention time of 2.841 minutes. Methanol was selected as the solvent for the analysis, with the λmax determined to be 223 nm. The method exhibited linearity over a concentration range of 5-30 g/mL. Validation parameters, including linearity, range, precision, accuracy, limit of detection (LOD), and limit of quantitation (LOQ), were assessed and met the required standards.

Opiniones del libro

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes