Impact of Sprinklers on the Fire Hazard in Dormitories: Sleeping Room Fire Experiments (en Inglés)

Nist (Autor) · Createspace · Tapa Blanda

Impact of Sprinklers on the Fire Hazard in Dormitories: Sleeping Room Fire Experiments (en Inglés) - Nist

Libro Nuevo Importado
Envío: 17 a 23 días háb.
$ 111.798$ 67.079
-40%
Costos de importación incluídos en el precio ✅
Libro Nuevo

Quedan más de 100 unidades

$ 67.079
Llega entre el 04 Ago y el 12 Ago a C.A.B.A., Ciudad Autónoma de Buenos Aires. Seleccionar ubicación

Reseña del libro "Impact of Sprinklers on the Fire Hazard in Dormitories: Sleeping Room Fire Experiments (en Inglés)"

The objective of this study was to compare the levels of hazard created by room fires in a dormitory building with and without automatic fire sprinklers in the room of fire origin. This report describes a series of experiments where fires were initiated in a dormitory sleeping room. The description of the experimental conditions includes: the geometry and construction of the building, the fuel load in the sleeping rooms, and the location of the instrumentation used to measure gas temperature, oxygen, carbon dioxide and carbon monoxide concentrations and heat flux. Smoke alarm activation and sprinkler activation times are also reported. Five experiments were conducted. In two of the experiments, the door between the sleeping room (room of fire origin) and the corridor was closed. In the other three experiments the door from the sleeping room (room of fire origin) remained open to the corridor. In each case, door closed or door open, one of the experiments was sprinklered. The results from the experiments comparing the sprinklered and non-sprinklered sleeping room are presented. The results from these experiments demonstrate the potential life safety benefits of smoke alarms, compartmentation, and automatic fire sprinkler systems in college dormitories and similar occupancies. These experiments were conducted by NIST in cooperation with the University of Arkansas and the Fayetteville Fire Department.

Opiniones del libro

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes