Pasaporte a Nuevas Historias: Recorré el mundo entre libros hasta 55% OFF en importados  Ver más

Enviar a
C.A.B.A., Ciudad Autónoma de Buenos Aires
0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional

Selecciona tu país

América

Europa

Resto del mundo

portada Analytical Study of Multistorey Building With or Without Softy Storey (en Inglés)
Formato
Libro Físico
Editorial
Idioma
Inglés
N° páginas
78
Encuadernación
Tapa Blanda
Dimensiones
22.9x15.2x0.4 cm
Peso
0.12 kg.
ISBN13
9789994985722
Categorías

Analytical Study of Multistorey Building With or Without Softy Storey (en Inglés)

Kiran Devi (Autor) · Pankaj Singh Khetwal (Autor) · Eliva Press · Tapa Blanda

Analytical Study of Multistorey Building With or Without Softy Storey (en Inglés) - Khetwal, Pankaj Singh ; Devi, Kiran

Libro Nuevo Importado
Envío: 16 a 21 días háb.
$ 173.101$ 86.550
-50%
Costos de importación incluídos en el precio ✅
Libro Nuevo

Quedan más de 100 unidades

$ 86.550
Llega entre el 25 Sep y el 02 Oct a C.A.B.A., Ciudad Autónoma de Buenos Aires. Seleccionar ubicación

Reseña del libro "Analytical Study of Multistorey Building With or Without Softy Storey (en Inglés)"

Multistorey buildings are becoming popular from the last few years due to their compact and space utilization concept due to increase in population and industrialization. This enables the accommodation of more people and offices in the vertical structure by using limited land area. The stability of structure is an important aspect against all the forces. The damage and collapse of any structure against the seismic forces may be due to structural irregularities i.e., horizontal or vertical irregularities. The discontinuity or drastic change in the lateral strength and stiffness of any storey in structure due to any reason become the main cause of failure against the seismic forces. The soft storey is one in which lateral stiffness is less than 70% of that in storey immediately above or less than 80% of the combined stiffness of three stories above. The effect of soft storey should be analyzed and structure should be designed to minimize their effects. The main purpose of this study is to compare the two cases of structure i.e., with and without soft story, under identical Indian standard loading conditions. Staad Pro is used for modelling and analysis of two almost identical models of 10 storey building (with soft or without soft story). The storey at middle of the building i.e. 5th storey of structure was considered as soft storey because it is not always possible for all terrains such as hilly terrains or corporate canteens to be at ground floor. From the analysis, it was found that one soft storey at middle height of structure causes structure to experience almost 50% increase of stresses.

Opiniones del libro

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes