Compartir
arteriovenous hemofiltration: a kidney replacement therapy for the intensive care unit (en Inglés)
Peter Krämer
(Ilustrado por)
·
Springer
· Tapa Blanda
arteriovenous hemofiltration: a kidney replacement therapy for the intensive care unit (en Inglés) - Kramer, Peter
$ 133.352
$ 222.253
Ahorras: $ 88.901
Elige la lista en la que quieres agregar tu producto o crea una nueva lista
✓ Producto agregado correctamente a la lista de deseos.
Ir a Mis Listas
Origen: Estados Unidos
(Costos de importación incluídos en el precio)
Se enviará desde nuestra bodega entre el
Lunes 27 de Mayo y el
Lunes 10 de Junio.
Lo recibirás en cualquier lugar de Argentina entre 1 y 3 días hábiles luego del envío.
Reseña del libro "arteriovenous hemofiltration: a kidney replacement therapy for the intensive care unit (en Inglés)"
Discovery and Relative Importance of Continuous Arteriovenous HemofIltration Lee W. Henderson Continuous arteriovenous hemofiltration (CAVH) has seen a brisk upswing in popularity in Europe since its introduction by Dr. Kramer and colleagues from Gottingen, West Germany in 1977 [1]. In the United States, the technique re- ceived approval as a clinical tool from the Food and Drug Administration in April 1982. This approval flowed, in no small measure, from the extensive expe- rience reported from Europe and in particular West Germany [e. g., 2, 3]. Reports of its clinical utility now have begun to appear in the United States [4]. Removal of excess total body water using synthetic membranes in an extracor- poreal circuit dates back to the work of Alwall and the artificial kidney that he designed which permitted utilization of a hydrostatic pressure gradient to moti- vate water flow across the membrane [5]. Kolffs original rotating drum with its unencased membrane required an osmotic driving force [6]. Hemofiltration, the use of the filtration process to remove uremic solutes with the artificial kidney, in analogy with the glomerulus, was reported in 1967 [7]. This was made possible by the availability of synthetic membranes with far higher hydraulic permeability (approximately 10 times higher) than conventionally used cellulosic hemodialysis membrane. Specific applications of these "high flux" membranes to the removal primarily of excess total body water followed shortly thereafter [8].
- 0% (0)
- 0% (0)
- 0% (0)
- 0% (0)
- 0% (0)
Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.
✓ Producto agregado correctamente al carro, Ir a Pagar.